CAN/CSA Z314.3-01 (R2006) PDF

CAN/CSA Z314.3-01 (R2006) PDF

Name:
CAN/CSA Z314.3-01 (R2006) PDF

Published Date:
01/01/2001

Status:
Active

Description:

Effective Sterilization in Health Care Facilities by the Steam Process

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$21.9
Need Help?


1. Scope

1.1
This Standard outlines essential elements in a program for using steam to sterilize medical devices in health care facilities, with the object of achieving an adequate level of sterility assurance and minimizing the risk of injury to the operators of steam sterilization equipment.
Notes:
(1) The term "health care facilities" includes, but is not limited to, hospitals, nursing homes, extended-care facilities, clinics, medical and dental offices, and health units in industry.
(2) Figure 1 shows the scope of this Standard within the reprocessing of reusable medical devices.
(3) Comprehensive guidance for small, office-based facilities can be found in CSA Special Publication PLUS 1112.

1.2
This Standard includes requirements for
(a) work areas;
(b) personnel qualifications and training;
(c) preparation and packaging of medical devices requiring sterilization;
(d) sterilizer loading and operation;
(e) storage of sterilized medical devices;
(f) sterility assurance, including test pack construction and use;
(g) product evaluation for sterilizable medical devices and packaging materials; and
(h) maintenance and sterilizer quality assurance.

1.3
This Standard does not apply to
(a) emergency (flash) sterilization;
Note: See CSA Standard Z314.13.
(b) construction and performance of steam sterilizers;
Note: See CSA Standard CAN/CSA-Z314.7.
(c) washer/sterilizers; or
(d) decontamination of reusable medical devices prior to sterilization.
Note: See CSA Standard Z314.8.

1.4
In this Standard, "shall" indicates a mandatory requirement; "should" indicates a recommendation or that which is advised but not mandatory; and "may" indicates an advisory or optional statement. Notes accompanying clauses do not include mandatory or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material that is not properly a part of the Standard. Notes to figures and tables are considered part of the figure or table and may be written as mandatory requirements; legends to figures are also considered part of the requirements of the figure.
File Size : 1 file , 1.3 MB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 64
Published : 01/01/2001

History

CAN/CSA Z314:23
Published Date: 01/23/2023
Canadian medical device reprocessing in all health care settings, Includes Update No. 1 (2024)
$181.5
CAN/CSA Z314-18
Published Date: 02/01/2018
Canadian medical device reprocessing
$158.7
CAN/CSA Z314.10.2-10 (R2015)
Published Date: 02/01/2010
Laundering, maintenance, and preparation of multiple-use gowns, drapes, and wrappers in health care facilities
CAN/CSA Z314.10.1-10 (R2015)
Published Date: 02/01/2010
Selection and use of gowns, drapes, and wrappers in health care facilities
CAN/CSA Z314.15-10 (R2015)
Published Date: 02/01/2010
Warehousing, storage, and transportation of clean and sterile medical devices
CAN/CSA Z314.8-08 (R2013)
Published Date: 03/01/2008
Decontamination of Reusable Medical Devices
CAN/CSA Z314.14-04
Published Date: 07/01/2005
Selection and Use of Rigid Sterilization Containers
CAN/CSA Z314.22-04
Published Date: 07/01/2004
Management of Loaned, Shared, and Leased Medical Devices, Includes Update No. 1 (2006)
CAN/CSA Z314.15-03 (R2008)
Published Date: 06/10/2003
Warehousing, Storage, and Transportation of Clean and Sterile Medical Devices
CAN/CSA Z314.10-03 (R2008)
Published Date: 04/14/2003
Selection, Use, Maintenance, and Laundering of Reusable Textile Wrappers, Surgical Gowns, and Drapes for Health Care Facilities
$27
CAN/CSA Z314.3-01 (R2006)
Published Date: 01/01/2001
Effective Sterilization in Health Care Facilities by the Steam Process
$21.9
CAN/CSA Z314.8-00 (R2005)
Published Date: 06/12/2000
Decontamination of Reusable Medical Devices
CAN/CSA Z314.10-97
Published Date: 03/21/2000
Selection, Use, Maintenance and Laundering of Reusable Textile Wrappers, Surgical Gowns and Drapes for Health Facilities
$11.1
CAN/CSA Z314.3-M91
Published Date: 01/01/1991
Effective Sterilization in Hospitals by the Steam Process
$12.6

Related products

CAN/CSA C22.2 NO. 601.2.17-94 (R99)
Published Date: 04/02/2000
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Remote-Controlled Automatically-Driven Gamma-Ray Afterloading Equipment (Adopted IEC 601-2-17:1989) / Appareils electromedicaux - Partie 2: Regles particulieres de securite pour appareils projecteurs de sources radioact
$20.4
CAN/CSA E79-15-95 (R1999)
Published Date: 01/19/2000
Electrical Apparatus for Explosive Gas Atmospheres - Part 15: Electrical Apparatus With Type of Protection "n" (Adopted IEC 79-15:1987, first edition)
$37.8
CAN/CSA C22.2 NO. 61010-2-045-04
Published Date: 07/01/2004
Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 2-045: Particular Requirements for Washer Disinfectors Used in Medical, Pharmaceutical, Veterinary and Laboratory Fields (Adopted CEI/IEC 61010-2-045:2000, first edition, 2000-09)
$48